ΕΙΣΟΔΟΣ
Number of MPP trackers | 1 |
---|---|
Max. input current (Idc max_inverter) | 87,5 A |
DC input voltage range (Udc min – Udc max) | 580 – 1000 V |
Feed-in start voltage (Udc start) | 650 V |
MPP voltage range (Umpp min – Umpp max) | 580 – 930 V |
Max. PV generator power (Pdc max) | 75 kWpeak |
Max. input current PV1 (Idc max, PV1) | 75 A |
Max. input current PV2 (Idc max, PV2) | 75 A |
Max. short-circuit current PV1 (Isc max, PV1) | 125 A |
Max. short-circuit current PV2 (Isc max, PV2) | 125 A |
Max. short-circuit current inverter (Isc max, inverter) | 178 A |
Max. power PV system PV1 (Pdc max,PV1) | 60 kWpeak |
Max. power PV system PV2 (Pdc max, PV2) | 60 kWpeak |
Number of DC connections PV1 | 1 |
Number of DC connections PV2 | 1 |
Max. AC fuse size rating | 355 A |
ΕΞΟΔΟΣ
AC nominal output (Pac,r) | 50 kW |
---|---|
Max. output power (Pac max) | 50 kVA |
AC output current (Iac nom) | 75,8A at 220Vac , 72,5A at 230Vac |
Grid connection (Uac,r) | 3~ NPE 380/220 , 3~ NPE 400/230 V |
AC voltage range (Umin – Umax) | 180 – 270 V |
Frequency (fr) | 50 / 60 Hz |
Frequency range (fmin – fmax) | 45 – 65 Hz |
Total harmonic distortion | <3,0% |
Power factor (cos φac,r) | 0 – 1 ind,/cap, |
ΓΕΝΙΚΑ ΧΑΡΑΚΤΗΡΙΣΤΙΚΑ
Width | 1109 mm |
---|---|
Height | 755 mm |
Depth | 346 mm |
Weight | 74 kg |
Weight incl. packaging | 93 kg |
Degree of protection | IP65 |
Protection class | 1 |
Overvoltage category (DC / AC) 1) | 2 / 3 |
Night-time consumption | 15W |
Installation | Indoor and outdoor 4) |
Ambient temperature range | -40°C – +65°C (optional AC-disconnect: from – 30 to + 65 °C) |
Permitted humidity | 0 – 100 % |
Max. altitude 2) | 4000 |
Certificates and compliance with standards | VDE-AR-N 4105, VDE-AR-N 4110, IEC 62109-1/-2, IEC 62116, IEC 61727 R25, AS/NZS 4777, CEI 0-16, CEI 0-21, EN 50549-1/-2, VDE 0126-1-1* |
Inverter topology | Transformerless |
Cooling | Active cooling technology and double wall system |
Interference emission class | B |
ΑΠΟΔΟΣΗ
Max. efficiency (PV – grid) | 98,5 % |
---|---|
European efficiency (ηEU) | 98,2 / 97,7 / 97,3 (580Vdc / 800Vdc / 930Vdc) |
η at 5% Pac,r 3) | 95,38 / 90,94 / 89,10 (580Vdc / 800Vdc / 930Vdc) |
η at 10% Pac,r 3) | 97,31 / 95,45 / 93,68 (580Vdc / 800Vdc / 930Vdc) |
η at 20% Pac,r 3) | 98,18 / 97,41 / 96,83 (580Vdc / 800Vdc / 930Vdc) |
η at 25% Pac,r 3) | 98,35 / 97,76 / 97,33 (580Vdc / 800Vdc / 930Vdc) |
η at 30% Pac,r 3) | 98,40 / 97,92 / 97,60 (580Vdc / 800Vdc / 930Vdc) |
η at 50% Pac,r 3) | 98,51 / 98,22 / 97,99 (580Vdc / 800Vdc / 930Vdc) |
η at 75% Pac,r 3) | 98,40 / 98,23 / 98,05 (580Vdc / 800Vdc / 930Vdc) |
η at 100% Pac,r 3) | 98,25 / 98,11 / 98,01 (580Vdc / 800Vdc / 930Vdc) |
MPP adaptation efficiency | 99,9 |
ΠΡΟΣΤΑΤΕΥΤΙΚΕΣ ΣΥΣΚΕΥΕΣ
DC insulation measurement | Included |
---|---|
Overload behaviour | Operating point shift. Power limitation 5) |
DC disconnector | Included |
DC Reverse polarity protection | Included |
Integral RCMU | Included |
Overvoltage protection devices | Type 1 + 2 integrated, Type 2 optional 6) |
ΔΙΕΠΑΦΕΣ
6x digital in/out + 6x digital in | Programmable interface for ripple control receiver, energy management, load control Inputs: Voltage level low: min. 0V – max. 1.8V; high: min. 4,5V – max. 28,8V / Input resistance: 70kOhm Outputs: 5 Watt @ 12V in total for all six digital outputs when supplied internally in case of no load on the USB Port. 1A @ >12,5V to 24V per digital output when supplied externally by an external power supply but in total max. 3A integrated |
---|---|
Emergency stop (WSD) | Yes |
Datalogger and web server | Included 7) |
WLAN | Fronius Solar.web, Modus TCP Sunspec, Fronius Solar API (JSON) |
2x RS485 | Modbus RTU Sunspec |
USB (type A socket) | 1 A supply |
Ethernet LAN RJ45 | 10/100Mbit; max. 100m Fronius Solar.web, Modbus TCP Sunspec, Fronius Solar API (JSON) 7) |
AC ΣΥΝΔΕΣΗ
Cable cross section | 35 – 240 mm² |
---|---|
Conductor material | Al; Cu |
Connection terminals | Cable lug or V clamps |
Single core option (single core cable) | Cable gland: 5 x M40 (10 – 28 mm) |
Multi core option (multi core cable) | Cable gland: 1 x multi core connection Ø 16 – 61.4 mm + 1 x M32 (10 – 25 mm) |
AC Daisy Chaining option (single core cable) | Cable gland: 10 x M32 (10 – 25 mm) |
DC ΣΥΝΔΕΣΗ
Cable cross section | 25 – 95 mm² |
---|---|
Conductor material | Al; Cu |
Connection terminals | Cable lug or V clamps, Cable gland: 6 x M40 |